Test of battery capacity
Panther Mini
Test:
Battery test is performed when running a distance of 25 m on
even floor, alternating with load (1000kg) and without load until
the battery indicator shows 0 % (80% discharged battery). The test
runs at least 10 hours.
Result:
PM 1401 with 2x 986500 Vision 12V 84 Ah/20h = 160 tons
PM 1401 with 2x 986034 semi track 12V 60 Ah/5h = 120 tons
PM 1401 with 2x 986040 Optima 12V 50 Ah/5h =120 tons
SELF Mini
Test:
Battery test is performed when running a distance of 25 m on
even floor, alternating with load (1000kg, lifted to 900mm) and
without load until the battery indicator shows 0 % (80% discharged
battery). The test runs at least 10 hours.
Result:
SELF MINI with 2x 986500 Vision 12V 84 Ah/20h =100 tons
SELF MINI with 2x 986034 mainte. free 12V 60 Ah/5h =75 tons
Twin Stacker
Test:
Battery test is performed when running a distance of 25 m on
even floor, alternating with load (1000kg on lowest forks and 500kg
on upper forks, lifted to 1770mm) and without load, until the
battery indicator shows 0 % (80% discharged battery). The test runs
at least 10 hours.
Result:
Twin Stacker with 2x 986520 Vision 12V 110 Ah/20h =180 tons
Panther Maxi
Test:
Battery test is performed when running a distance of 25 m on
even floor, alternating with load (1500kg) and without load until
the battery indicator shows 0% (80% discharged battery). The test
runs at least 10 hours.
Result:
PM 1801 with 2x 986520 Vision 12V 110 Ah/20h =330 tons
PM 1801 with 986200 Tubular cell 24V 120 Ah/5h =330 tons
PM 1801 with 4x 986040 Optima 12V 50/5h AH =250 tons